SKC Personal Samplers

Specifications

OPERATING 1-5000 ml/min (1-500 ml/min
RANGE: REQUIRES LOW FLOW CONTROL)

WEIGHT: 34 oz.

DIMENSIONS: 1-15/16" x 4-11/16" x 5-1/8";
44.7 cubic inches (732 cubic centimeters)

COMPENSATION 750 ml/min - 5" to 40” Water Back Pressure
RANGE: 1000 ml/min - 0" to 40" Water Back Pressure
2000 ml/min - 0" to 40" Water Back Pressure
2500 ml/min - 0" to 40" Water Back Pressure
3000 ml/min - 0" to 35" Water Back Pressure
4000 ml/min - 0" to 20" Water Back Pressure
5000 ml/min - 0" to 15" Water Back Pressure
FLOW
CONTROL: ±5% Set Point Constant Flow

RUN TIME: 8 hours minimum at 4000 ml/min and 20" water
back pressure

FLOW
INDICATOR: Built in Flow Indicator with 250 ml division;
scale marked at 1, 2, 3, 4, & 5 LPM

BATTERY Plug in battery pack, Rechargeable NiCad
ASSEMBLY: 2.0 AH, 6.0 V. U/L Listed. Contains
receptacle for charging out of pump.

INTRINSICALLY
SAFE: UL Listed for Class I, Groups A, B, C, D;
Class II, Groups E, F, G; and Class III. Temp Code T3C.

OPERATING
TEMP: -20°C to +45°F;
(-4°F to +113°F)
STORAGE TEMP: -40°C to +45°C
(-40°F to +113°F)
CHARGING TEMP: +5°C to +45°C
(+41°F to +113°F)
OPERATING
HUMIDITY: 0 to 95% Relative

MULTIPLE
SAMPLING: Built in constant, pressure
regulator allows user to take up to four simultaneous samples of up to 500 ml/min each (total combined flow 1350 ml/min maximum) using optional low flow control.

ADDITIONAL
SPECIFICATIONS: * Built, in fluid/particulate
trap
* External see-through filter
housing
* Anti-tamper control cover
* Anti-tamper compensation
adjustments
* Accessory mounting provisions
* Stainless steel belt clip
* External exhaust port
* All non-plastic parts made of
corrosion resistant materials


SKC Personal Samplers

SKC 224-PCX7S

Specifications

Operating Range:

l-5000ml/min (l-500ml/min Requires Low Flow Control)

Weight: 34 ounces
Dimensions: 1- 15/16" x 4- 11/16" x 5- 1/8"; 44.7 cubic inches (732 cubic centirneters)
Compensation Range: 750 ml/min - 5" to 40" Water Back Pressure
1000 ml/min - 0" to 40" Water Back Pressure
2000 ml/min - 0" to 40" Water Back Pressure
2500 ml/min - 0" to 40" Water Back Pressure
3000 ml/min - 0" to 35" Water Back Pressure
4000 ml/min - 0" to 20" Water Back Pressure
Flow Control: ± 5% Set Point Constant Flow
Run Time: 8 hours minimum at 4000 ml/min and 20" water back pressure
Flow Indicator: Built-in Flow Indicator with 250 ml division; scale marked at 1, 2, 3, 4, & 5 LPM
Battery Assembly: Plug in battery pack, Rechargeable NiCad 2.0 Ah, 6.0 v. U/L Listed. Contains receptacle for charging out of pump.
Intrinsically Safe: UL Listed for Class I, Groups A, B, C, D;
Class II, Groups E, F, G; and Class III.
Temp Code T3C.
Operating Temp: -20°C to +45°C (-4°F to +113°F)
Storage Temp: -40°C to +45°C (-40°F to +113°F)
Charging Temp: +5°C to +45°C (+41°F to +113°F)
Operating Humidity: 0 to 95% Relative
Flow Fault: Fault Shutdown with LCD Indicator and Time Display Retention if flow is restricted.
Battery Test: LCD Indicator verifies battery condition prior to test.
Time Display: LCD Indicator displays time in minutes sampler run time, sampling period elapsed time or total elapsed time including delayed start time).
Delay On: Allows user to select minutes to delay start of test up to 9999 minutes (7 days).
Timed Shutdown: Allows user to select minutes of operation before automatic shutdown.
Timing Accuracy: ± .05% (± 45 seconds/day)
Intermittent Sampling: Programmable to allow user to extend short term samples over an extended period of time to meet time weighted average requirements with a reduced number of samples. Elapsed time maximum is 9999 minutes (7 days).
Sampling Pause: Allows user to temporarily halt sampling without loss of timing or programming data. Restart does not require resetting time.
Multiple Sampling: Built-in constant pressure regulator allows user to take up to four simultaneous samples of up to 750 ml/min each (total combined flow 1350 ml/min maximum) using optional low flow control.


GILIAN LFS 113 AIR SAMPLER

Specifications

Operation Range

Constant flow mode: 5-200 cc/min., back pressures to 25" H20
Constant pressure mode:
(multi-tube) 1-350 cc/min. with flows adjustable through a single or multiple tube flow controller.

PRESSURE RANGE backpressure up to 25" H2O
FLOW CONTROL ± 5% of set point
BATTERY SYSTEM Rechargeable, plug in, 4.8V, 500 mAh Ni-cad battery pack. Designed to meet all UL requirements. Internal charging, (external charging with adapter).
SIZE 2-1/2" W x 1-3/8" H x 4-5/8" L
WEIGHT 12 ounces
TEMPERATURE

Operating: -20 to 45 °C, Storage: -40 to 45 °C, Charging: +5 to 45 °C
ADDITIONAL FEATURES Flow fault indication LED, battery check LED, belt clip, dual filtration system, sorbent tube end breaker, external flow adjust.


GILIAN HFS 113A AIR SAMPLER

Specifications

OPERATING RANGE

HIGH FLOW ½ - 3 ½ LPM.
LOW FLOW
1 cc to 500 cc/min, achieved through use with variable flow controller. This unique feature allows very low flows as well as two or more simultaneous, independently settable samples.

PRESSURE RANGE: 500 cc - 25" 3000 cc - 15"
1000 cc - 30" 3500 cc - 8"
2000 cc - 20"
FLOW CONTROL ± 5% of set point
FLOW INDICATOR Built-in flow meter, range 0 to 4 LPM, with 200 cc/div scale marked at 1, 2, 3 and 4 LPM.


GILIAN HFS 513A AIR SAMPLER

Specifications

Operation Range

HIGH FLOW 750 to 5000 cc/min. constant flow sampling
LOW FLOW
1 to 750 cc/min. constant pressure sampling Ideal for multiple tube sampling at independently set flow rates. Achieved through use of variable flow controller tube holder configuration.

PRESSURE RANGE 750 cc/35" H20, 1000 cc/40", 2000 cc/40", 3000 cc/35", 4000 cc/20", 5000 cc/10"
FLOW CONTROL ± 5% of set point
FLOW INDICATOR Built-in flow meter, range 0 to 4 LPM, with 200 cc/div scale marked at 1, 2, 3 and 4 LPM.
FLOW FAULT INDICATOR LED fault indicator will light immediately if the unit is operated out of its performance envelope. The pump will run for another 15 to 30 seconds before shutting down and the LED will remain illuminated.
BATTERY TEST When Press-to-Test is depressed, the Battery LED will illuminate indicating that the battery will provide a minimum of 8 hours of operation over the operating range.
BATTERY A plug-in rechargeable Ni-Cad battery pack, 1.8 Ah, 6.0V, UL listed. Can be recharged internally or externally with use of adapter.
INTRINSIC SAFETY RATINGS UL listed for classes I, II and III - groups A, B, C, D, E, F & G for explosive gas and dust atmospheres. SCS (SIRA Certification Service) listed Certificate No. Ex91C2018X, Coding: EEx iB IICT4
COMPACT SIZE 1 7/8" x 4 5/8" x 5 1/8" (44.7 cubic inches) (732 cubic centimeters)


Mini-Buck M-30 Calibrator

Specifications

Operating Range

M-5 1-6,000 cc/min
M-30 .100 cc to 30 liters/min.

Flow Control

Electronically-calculated and microprocessor-controlled to ensure accurate and repeatable measurements within ±0.5%.
Accuracy

±0.5% at any altitude
Dimensions / Weight
5-1/2" x 6" x 2-1/2" / 26oz
Case

Rugged molded polycarbonate case
Battery

Rechargeable nickel cadmium batteries 8-hour continuous-life (with full charge).
Battery Check Indicator

Red LED lights when recharging is necessary.


BIOS DryCal DC-2M

General Specifications

Dimensions:

5 1/4" W x 9 5/8" D x 7 3/4" H
Weight: 3.25 Ibs.
Flow Ranges
Interchangeable cells (Same as DC-1)
1 ml to 9.999ml/min (DC-1 LC cell)
10 ml to 9.999L/min (DC-1 SC cell)
50 ml to 50 L/min DC-1 HC ce

Accuracy 1%
Power Rechargeable Lead-Acid battery
Operating Readout: Volume flow, instantaneous
Volume flow, average
Standardized flow, instantaneous
Standardized flow, averaged
Number of readings in average
Idling readout Date
Time
Barometric pressure
Temperature
Data Logging outputs Parallel Printer (IBM/Centronics)
RS-232
Data Logging Modes Continuous
Bursts and averages of n samples
Intermittent (Every 1 to 255 minutes)
Units IBM PC or 100% compatible with at least one open serial port, a CGA, EGA, HGA, VGA or other adapter capable emulating these standards.


Highlights

Primary Flow Standard
Certified NIST Traceable
5-Minute Auto Shut-Off
Simple Push-Button Operation
Immune to Flow Source Pulsation
Fast & Accurate
Features

Simple Operation
Provides the user with accurate volumetric flow readings with the push of a button. No training required.

Continuous Auto-Mode
Flow readings can be taken continuously, in the auto mode, providing hands-free operation. This feature enables the user to quickly adjust the flow source to a precise flow rate saving time and money.

Immune to Flow Source Pulsation
DC-Lite needs NO in-line dampers.

Flow Cell Volume Certified NIST Traceable
The flow cell is made of dimensionally stable Borosilicate glass and is manufactured and characterized to ±0.00005 inch tolerance. At BIOS each cylinder is re-measured with NIST traceable standards and certifying documentation is provided for each unit.

Crystal Timing Mechanism is Tested With NIST Traceable Frequency Counter
That is periodically re-certified by a NIST traceable laboratory.

Patented Graphite Composite Piston Assembly
Eliminates the inherent inaccuracies and mess associated with bubble soap.

Sealed Lead Acid Battery
Eliminates NiCad battery problems; memory effect and battery burnout from overcharging. Allows AC/DC operation. The DC-Lite can be used while charging.

Alphanumeric Display (LCD)
Indicates flow rate, flow average and number of readings included in average.
(10 readings per averaging sequence)

5-Minute Auto Shut-Off
Preserve battery life and ensure deployment resources with DC-Lite's 5-minute auto shut-off function.

Built-In Flow Cell Integrity Test
Quality assurance self-test allows user to periodically verify proper flow cell integrity.

DryCal Has Been Tested By NIST
And the Japanese National Laboratory of Metrology and was found to be within ±0.2% of their transfer standards.

Built-in Parallel Printer Port
Interfaces with IBM compatible printers.

Specifications

Size:

5"W x 2-3/4"D x 5"H

Weight:

30 oz. / 851.25 g

Models

Basic Flow Ranges

Extended Flow Range

DCL-L Low Flow:

10 to 500 ml/min

None

DCL-M Medium Flow:

100 ml/min to 7 Lpm

7.001 Lpm-12Lpm

DCL-H High Flow:

500 ml/min to 30 Lpm

None

DCL-ML:

50 ml/min to 2 Lpm

2.001 Lpm-5 Lpm

DCL-MH:

20 ml/min to 20 Lpm

None

Battery System:

6V Rechargeable, Sealed lead-acid, 6-8 hours typical operation

AC Battery Charger:

Wall-mounted single-station
Input: 100 to 120 VAC, 50 to 60 Hz
Output: 12VDC, 2.5mm charger plug, center positive (Optional: 200 to 240 VAC, 50 to 60 Hz)
The charger can be used for AC operation.


Gilian Gilibrator Calibrator

General Specifications

Flow Cell Assembly Ranges Available

High Flow Cell 2 - 30 LPM
Standard Flow Cell 20 cc/min. - 6 LPM
Low Flow Cell 1 - 250 cc/min.

Operational Features

Direct Flow Readings - The easy to read LCD read-out on the Control Unit (base) instantly displays flow readings.

Auto Averaging - A switch on the Control Unit provides Auto-Averaging of the successive flow readings.

Flow Delete Function - A Flow Delete switch allows the user to delete erroneous flow readings from the Auto-Averaging function. For example, if a double bubble or other obvious malfunction is observed, that reading can be subtracted from the auto-average and will automatically reset the average to its previous value.

Programmable Update - The micro-processor electronic design allows programmable updates to assure a long useful service life.

Mechanical Features

Pulsation Damper - The pulsation damper removes pulsation from the flow source for higher accuracy sampling as well as eliminating pulsations back into the flow source during bubble generation.

Ring Bubble Generator - The Ring Bubble Generator lifts an even soap film from the soap reservoir and provides consistent bubble generation.

Bubble Breaker - The Bubble Breaker design allows the soap film to be drawn away form the end of the flow tube before bursting. This improves flow measurement accuracy by minimizing film residue within the flow tube.

Programmable Update - The electronics design allows programmable updates to assure a long, useful service life.

Accuracy - Better than 0.5%


SKC Cyclones for Respirable Dust and Cassette Holder Specifications Cyclone Sampling The ACGIH, International Organization for Standards, and European Standard Committee (ISO/CEN) specify a collection efficiency curve with a median cut-point at 4.0 mm. When performing respirable dust sampling with cyclones, it is important to adjust the flow rate to give the closest possible match over the whole curve (not just a single point). The ACGIH/ISO/CEN curve (Soderholm Convention) requires using the flow rate which minimizes the bias of the cyclone separation from the convention curve. A leading aerosol research organization has calibrated the SKC aluminum cyclone and the results were carefully evaluated for bias over the whole curve, showing that 2.5 L/min* most closely matches the convention curve. The SK.C Aluminum Cyclone now meets the ACGIH/ISO/CEN Convention, at 25 L/min, specified in NIOSH method 0600 (4th ed.). The cyclone can also be operated at 1.9 L/min to meet the BMRC (British Medial Research Council) curve, which stipulates a 5 mm cut-point. *As previously published, a flow rate of 2.6 L/min will give a 4 mm cut-point, however, 2.5 L/min will give a better match over the entire curve. Filter Cassette Holder The Filter Cassette Holder may be used with 37 mm cassettes directly, or with 25 mm cassettes using the O-ring adapters supplied. Operation 2-or-3 piece 37mm Cassettes without Cyclone - Orient the Cassette Holder so that the collar clip is at the top. Pull back the spring-loaded hold-down plate, and place the loaded cassette over the large hold on the holder so that the cassette inlet is facing down over the hold. Position the small hole in the hold-down plate over the cassette outlet. Connect the dark rubber tubing (with adapter) through the hold-down plate and into the cassette outlet. 2-or 3-piece 25 mm Cassettes without Cowl - Insert the cassette into the O-ring supplied, and position the O-ring at the joint between sections of the cassette. Position the cassette In the holder and attach the tubing as described above. 25 mm Cassette with Cowl - Remove the inlet piece of a 3- piece 25 mm cassette. Insert the cowl and apply a Cassette Sealing Band. Slip the O-ring (supplied) over the cassette and position the O-ring at the joint between the cassette and the cowl. Insert the cowl through the large hole in the holder until the O-ring contacts the holder. Continue with the hold-down plate and tubing as described above.


 

Ludlum M3 Survey Meter

Specifications

Power two standard "D" size batteries
Four Linear Ranges range multiples of XO.I, XI, XIO, XIOO
Sensitivity 30 millivolts, (±10 mV)
Audio built-in unimorph speaker with an ON-OFF switch
High Voltage externally adjustable from 400 to 1500 volts
Response Four or twenty-two seconds for 90% of final meter reading
Linearity plus or minus 5% full scale
Battery Life 300 HOURS with fresh set of alkaline batteries.
NOTE: Battery life will deplete rapidly in extreme cold weather.
Calibration Stability less than 3% variance to battery endpoint
Meter 1mA, 2 1/2-inch scale, with pivot-and-jewel suspension
Meter Compensation A temperature compensation package is mounted internally; located behind meter movement.
Connector Series "C", 706 U/G; BNC or MHV may also be provided
Size 10.67cm (4.2')H X 8.9cm (3.5")W X 21.6cm (8.5")L, exclusive of handle
Weight 1.36kg (3 lbs.) less detector and batteries
Finish drawn-and-cast aluminum, with computer-beige polyurethane enamel and
silk-screened nomenclature


 

HI-1501 Microwave Oven Survey Meter SPECIFICATIONS

Frequency: 2450Mhz

Ranges: 0-2, 0-10, 0-100 mW/cm2

Response Time:

90% of final value for a step input Fast: 1 second. Slow: 2.5 seconds

Maximum power density: 2.0 W/ cm2

Probe length: cm (12 inches)


 

Honeywell Professional Radon Monitor and Data Logger/Printer

Specifications

IMPORTANT
THE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL
MANUFACTURING TOLERANCES. THEREFORE, THIS UNIT MAY NOT MATCH THE LISTED SPECIFICATIONS EXACTLY,ALSO, THIS PRODUCT IS TESTED AND CALIBRATED UNDER CLOSELY CONTROLLED CONDITIONS, AND SOME MINOR DIFFERENCES IN PERFORMANCE
CAN BE EXPECTED IF THOSE CONDITIONS ARE CHANGED.

Model

A900QA Professional Radon Monitor.

Radiation Detected Alpha partical emission from radon / radon progeny atomic dacay.
Detection Method Silicon detector
Measurement Range 0.1 to 999 picocuries per liter(pCi/l).
Nominal Sensitivity 1 alpha decay per hour/pCi/l,@4pCi/l.
Backup Batteries Two 9 V alkaline batteries.
Battery Life Approximately 5-7 hours continuous operation (batteries only for short term backup use to maintain microprocessor memory and measurement function in case of power outage.
Display 3 digit, LED digital display.
Power 10.1 W. 18 VDC from conveter plugged in to 120 Vac, 60 Hz house circuit.
Dimensions 5 in. (127 mm) diameter x 7 in. (178 mm) high
Weight 2 lb. [0.9 kg].
Parts and Accessories Power Converter Part No. 201648.
Monitor Carrying Case Part No. 201710A.
9V alkaline batteries(2).
Q9010A Data Logger Printer Specifications
Model Q9010A QA Data Logger Printer
Prints Memory 8,000 character capacity
Character Matrix 6x8 dot matrix
Line Spacing 7.6 lines/in. character mode. 9.1 lines/in. graphic mode.
Print Speed 38 lines/Minute (24 column).
Printer Paper Roll 2.25" width x 2.75" diameter: 0.44" inside diameter.
AC Voltage 9 Vac (plug in 120 Vac. 60 Hz transformer).
Operating Temperature 40 deg F to 105 deg F(C to 40 C).
Parts and Accessories Printer ribbon cartrige,Epson HX-20 Cartridge.


 

Alnor 6000 AP Velometer

Specifications
Accuracy
Velocity

± 2% of full scale, all ranges

Static Pressure ± 5% of full scale, all ranges
Read-out time 4 to 8 seconds
Dimensions (Meter) 6 ½ x 6 x 2 ½ inches
Weight 1.75 Ibs.
Ranges (Scale markings)
6006-AP Velocity 0 to 300, 1250, 2500, 5000, 10000 FPM (0 to 1.5, 6.25, 12.5, 25, 50 meters/sec)
Static Pressure 0 to 1.0, 10.0 in. water (0 to 25, 250 mm.)


 

Velocicalc Plus Model 8360

Specifications

Range 30 to 500 ft/min 500 to 2000 ft/min 2000 to 6000 ft/min 6000 to 9999 ft/min 0.15 to 2.5 m/s 2.5 to 10 m/s 10 to 30 m/s 30 to 50 m/s
Accuracy 2.5% rdg ±2 ft/min 2.5% rdg ±10 ft/min 2.5% rdg ± 50 ft/min 2.5% rdg ± 100 ft/min 2.5% rdg ±0.01 ft/min 2.5% rdg ± 0.05 m/s 2.5% rdg ± 0.25 m/s 2.5% rdg ± 0.5 m/s


 

Model 8330 Features

Extended velocity range of 0 to 20.00 m/s
Temperature range of -18 to 93°C
Easy-to-read digital display
Slow and fast time constant modes available to smooth the display when measuring fluctuating flows
94.0 cm telescoping probe provides exceptional convenience in difficult situations
Includes a battery check that monitors battery level to ensure accurate readings
NIST*-traceable calibration certificate


 

Alnor Compuflow Thermoanemometer Model 8565

Specifications
INSTRUMENT DISPLAY 4-digit, 5/16" high LED's. Separate indication for FPM, m/s, °F, °C and HOLD
AIR VELOCITY RANGE

20 to 3000 FPM (0.1 to 15 m/s)

INSTRUMENT TEMPMEASURING RANGE 32 to 158°F (0 to 70°C)
OPERATIONAL RANGE
Instrument: 32 to 122°F (0 to 50°C)
Probe: 32 to 158°F (0 to 70°C)
ACCURACY
Air velocity* (Air Temp. 75-79 °F, 24-26 °C):
20-100 FPM
100-600 FPM
600-3000 FPM ± 5 FPM (± .03 m/s)
± 3% of reading ± 2 FPM (± .01 m/s)
± 3% of reading ± 20 FPM (± 0.1 m/s)
Temperature: ± 0.8°F (± 0.4°C)
Temperature Drift*: ± ¼% of reading or 1/4 FPM (whichever is greater) for each °C change in Air Temperature
RESOLUTION
Air Velocity: 1 FPM from 20 to 700 FPM
(.01 m/s from .1 to 3.55 m/s)

10 FPM from 700 to 3000 FPM
(.1 m/s from 3.55 m/s to 15 m/s)

Temperature: 0.1°
BATTERIES Three 1.2V C-size rechargeable 2200 mAH NiCd cells
BATTERY RECHARGE TIME 12 to 14 hours
BATTERY LIFE Minimum 6 hours continuous service (without printer in use)
INSTRUMENT DIMENSIONS 2 3/4" x 4"x 7 1/2" (70 x 102 x 190 mm)
INSTRUMENT WEIGHTWITHOUT PROBE 1 lb. 7 oz. (651 grams) with batteries
CARRYING CASE Black plastic, foam padded; 17 1/4 " x 4 5/8" x 14" (430 x 117 x 356 mm), with handle
TELESCOPIC PROBE 355 " (9 mm) max diameter Handle 3 1/2" long x 1 1/2" wide Length 20" closed, extendible to 45". (508 mm extendible to 1143 mm)
Flexible cable 7 ft. (2.1 M) long
Pivoting section 4.5" (114 mm) long at tip end, lockable in straight or either 90° position.
Flex life: 2000 cycles minimum.
PRINTER PORT For use with ALNOR CompuFlow Microprinter
P/N 638-493-000 or CompuFlow RS232 interface module P/N 639-000-000
FIELD CALIBRATIONADJUSTMENT RANGE ± 20% change from factory calibration
Specifications subject to change without notice.
* These specifications are valid only if measurements are taken in a 4" dia. or larger duct or free air, the temperature gradient across the duct is less than 0.1°C, and the turbulence level is less than 1.5%.


 

SHORTRIDGE FLOW HOOD

Specifications

AIR FLOW: Measured in cubic feet per minute (cfm) and litres per second (L/s). Measurement range is 30-2000 cfm supply and 30-1400 cfm exhaust.
ACCURACY: ±3% of scale or better.
DENSITY STANDARD: Constant volume standard conditions of .075 Ibs/cu ft air density.
CALIBRATION: Certified, electronic hook gauge traceable to N.B.S.
METER: Mechanical deflecting vane type anemometer.
FLOW RESISTANCE: .0075 in wc @ 500 cfm.
READOUT TIME: 4 to 8 seconds full scale
BASE: High impact, molded T grade ABS.


 

HHPC-6 Specifications

6 Size Channels 0.3 µm; 0.5 µm; 0.7 µm; 1.0 µm; 2.0 µm; 5.0 µm
Flow Rate 0.1 CFM (2.83 l/min.)
Light Source Laser Diode; Index Guided
MBTF > 36,000 hours @ 25°C
Calibration PSL particles in air (NIST Traceable)
Counting Efficiency 50% @ 0.3 µm; 100% for particles > 0.45 µm (per JIS B9921)
Zero Count < 1 count/5 minute (per JIS B9921)
Coincidence Loss 5% at 2,000,000 particles per ft3
Data Storage 500 Sample Records
Data Recorded Date, time, counts, R/H, temperature, sample volumes, alarms, label
Display Graphic liquid crystal with back light
Alarms Counts, low battery, sensor fail
Count Modes Concentration, Totalize, Audio
Delay Time 0 ~ 24 hours
Sample Inlet Isokinetic probe
Interface RS-232 and RS-485 via RJ-45
Vacuum Source Internal pump flow controlled
Housing Injection molded plastic with internal, conductive coating
Dimensions 4.5" (w) x 8.25" (l) x 2.25" (d); (11.43 cm x 20.96 cm x 5.72 cm)
Weight 2.2 pounds, 1 kg
Power

AC Adapter 12 VDC at 2.5 A, 90 - 250 VAC, 50 -60 Hz
Rechargeable Battery NiMH, 4.8 V at 4.5 Ah; Replaceable
Continuous Operating Time 8 hours
Recharge Time 2 hours
Operating Conditions

Relative Humidity 20 to 90%, non-condensing
Temperature 10 to 40°C (50 to 104° F)
Storage Conditions

Relative Humidity Up to 90%, non-condensing
Temperature -10 to 50°C (14 to 122°F)
Accessories Options

Screw-on Iso Probe Serial Printer with Cable
Operation Manual Carrying Case
Utility Software Zero Count Filter
1/8in. Hose Barb Adapter

Standards
JIS B9921


 

Specifications
P-TRAK ULTRAFINE PARTICLE COUNTER

Concentration Range
0 to 5 x 105 particles/cm3
Particle Size Range
0.02 to greater than 1 micrometer
Temperature Range
Operation
Storage

32 to 100o F (0 to 38o C)
-40 to 160o F (-40 to 70o C)
Flow Rate
Sample
Total

Approx. 100 cm3/min
Approx. 700 cm3/min
Memory
Single points
Datalogging

470 points
Adjustable interval (up to 1,000 hrs. of data at 1 minute intervals)
Storage of up to 141 separate tests
Power Requirement
Battery type
Battery life

6 AA Alkaline
6 hrs @ 70o F (21o C)
Alcohol Requirement
Type
Hours per charge

100% reagent grade is isopropyl
8 hours at 70o F (21o C)
RS232 Output
Baud rate 9600 (8-N-1)
Size
10.75 in. x 5.5 in. x 5.5 in.
(27 cm x 14 cm x 14 cm)
Carrying Case
Size

21 in. x 14 in. x 8.3 in.
(53 cm x 36 cm x 21 cm)
Weight
Instrument with batteries
Instrument with accessories in case
Shipping weight

3.8 lbs (1.7 kg)
16.8 lbs (7.7 kg)
23 lbs (10.5 kg)
Factory Service Interval
One year
Warranty
Two years on parts and labor


SPECIFICATIONS:
DUSTTRAK Aerosol Monitor / Model 8520

Specifications are subject to change without notice.

Sampling Conditions:
Operating Temperature:………… 0 ºC to 50 ºC (32 ºF to 120 ºF)
Wind Speed: ………………. 0 m/s to 10 m/s (0 mph to 22.5 mph)
Aerosol Concentration
Range: ……………………………. 0.001-100 mg/m³ (calibrated to respirable fraction of standard ISO 12103-1, A1 test dust)
Storage Temperature: ………….. -20 ºC to 60 º(-4 ºF to 140)
Zero stability: ………………………±0.001 mg/m³ over time-constant
Particle size range: ……………… 0.1-approximately 10 µm (Upper limit is dependent on flowrate)
Flowrate: ………………………….. 1.7 L/min.
Temperature coefficient: …………+0.001 mg/m³ per ºC (for variations from temperature at which DustTrak monitor was zeroed)

Phisical:
External dimensions: …………….406 mm x 330 mm x 191 mm (16 in. x 13 in. x 7.5 in.)
Weight (with battery and
DustTrak monitor): ……………… 7.2 kg (15.8 lb.)


 

MIE PDM-3 Miniram

Specifications

Measurement Ranges (auto-ranging):
0.01 to 10 mg/rn3
0.1 to 100 mg/m3
Precision (2-sigma):
± 0.02 mg/m3 (10-sec. measurement at constant temperature)
Particle Size Range of Max. Response:
0.1 to 10 um
Display Selection:
10-second concentration, time-weighted average, 8-hour shift average, elapsed sample time, zero level, ID number, program code
Data Storage:
7 concentration averages (500 minutes max. each) with timing
Outputs:
Analog (0 to -1.5V), digital ASCII, switched alarm
Operating Time:
12 hours (fully charged battery), continuously with included charger
Operating Temperature:
0 to 50 °C (32 to 120 °F)
Dimensions:
10 x 10 x 5 cm (4" x 4" x 2")
Weight:
0.45 kg (16 oz.)


 

Andersen N6 Bioaerosol Kit

Specifications
The Andersen 1 ACFM Viable Particle Sampler is constructed with six aluminum stages that are held together by three spring clamps and gasketed with 0-ring seals (Figure 2). Each impactor stage contains multiple precision drilled orifices. When air is drawn through the sampler, multiple jets of air in each stage direct any airborne particles toward the surface of the agar collection surface for that stage. The size of the jet orifices is constant for each stage, but is smaller in each succeeding stage. The range of particle sizes collected on each stage depends on the jet velocity of the stage and the cutoff of the previous stage. Any particle not collected on the first stage follows the air stream around the edge of the Petri dish to the next stage.

Each stage contains 400 orifices with diameters ranging from 1.81 mm on the first stage to 0.25 mm on the sixth stage. Each stage has a removable glass Petri dish with metal cover. The exhaust section of each stage is approximately 19 mm larger in diameter than the Petri dish which allows unimpacted particles to go around the dish and into the next stage (Figure 3).

The Andersen Six-Stage Viable Particle Sampler and Vacuum pump include their own carrying cases for ease of portability (Figure 4). Case dimensions are 9 3/8" wide x 8 3/4" high x 5" deep. Complete sampler and vacuum pump weights including carrying cases are 6 1/4 pounds and 12 pounds respectively.

A constant air sample flow of 1 ACFM is provided by a continuous vacuum pump. Flow rate is controlled by an adjustable valve on the pump and periodic calibration is recommended.


 

Delmhorst DP Moisture Meter

The Moisture Detector Model BD is a portable, battery powered instrument used to determine the moisture level.

- in plaster walls and siding prior to painting
- in concrete slabs before installing floor covering
- in roof decks and insulation
- in wall insulation

Features:

Digital readout
Three scales:
Wood Scale - 6% to 40% moisture range. Use for flooring and building material such as wood studs, floor joists, sub floors
Reference Scale reads from of 0 to 100 on a relative basis. Use on non-wood materials such as concrete, plaster, and insulation
Gypsum Scale - 0.2%-50% moisture range. Use on sheetrock.
Averages up to 100 accumulated readings
Set-point alerts you to when a pre-selected MC is reached
Connector to attach #21-E or #26-ES electrode for deep penetration
One year warranty
Truly one of the most versatile moisture meters available today, the BD-2100 is perfect for the professional contractor.
The BD series, purchased individually, includes a carrying case and extra #2497/A-100 contact pins. Or choose from two different packages depending on your needs.
The standard package includes a moisture meter, carrying case, #21-E electrode and extra #2497/A-100 contact pins.
The flooring package includes the moisture meter, carrying case, , #26-ES, and extra #496 and #2497/A-100 contact pins.


 

ALLERGENCO AIR SAMPLER - MK-3 SPORE TRAP
PROVIDES BIG MACHINE PERFORMANCE IN A SMALL PACKAGE
HIGH-TECH SIMPLIFIES AIR SAMPLING
Our goal is to combine research and support for the allergy and environmental professions with the best possible publications and equipment. Having provided the reference book, SAMPLING AND IDENTIFYING ALLERGENIC POLLENS AND MOLDS (1990) by E. Grant Smith, to use in identifying airborne pollen grains and fugal spores in air samples, we offer what we believe is the best, simplest to operate, and most reasonably priced device for particulate collection.

The patented ALLERGENCO AIR SAMPLER MK-3 is a highly efficient "grab-type- volumetric air sampler that collects multiple, discrete samples on laboratory slides according to a programmed cycle established by the user and variable almost without limit. Samples are visible as thin traces I.I mm x 14.5 mm and 2 mm from center to center.
The user-friendly ALLERGENCO AIR SAMPLER MK-3:

Can be programmed to collect up to 24 discrete samples during any given unattended period. HIGHLY
EFFICIENT AND AUTOMATIC FEATURES MAKE IT ESPECIALLY USEFUL BOTH INDOORS AND OUTDOORS.
IS SIMPLE TO PROGRAM. The count down of sampling time and the time remaining until the
next sample is clearly visible in the LCD display.
WILL REPEAT PROGRAMMED CYCLE UNTIL CHANGED. Reprogramming is simple; changes
can easily be done on site without additional equipment.
IS SOLIDLY CONSTRUCTED with operating prompts printed inside lid to provide brief user
instructions.
USES REGULAR 25 MM X 75 MM LABORATORY SLIDES coated with hexsilicon or silicone
grease. The slide is placed on a solid brass holder during sampling and simply lifted off with the sample period is completed. ADD STAIN AND COVER SLIP AND YOU ARE READY TO START COUNTING. Permanent reference slides can be made with ease.
Is small (measures 6 1/8"[L] x 3 3/4"[W] x 5"IH]; weighs approximately 4 Ibs.). High efficiency and automatic features make it ESPECIALLY USEFUL FOR INDOOR SAMPLING. It is dependable and practical for indoor air quality investigators to perform quantitative analysis.
Samples 15 liters of air per minute and produces allergen counts 3 to 5 times higher than rotary samplers
operating under identical conditions. Sampling time can be changed quickly to any period from one minute to 24 hours with a single button located next to LCD read-out window.
Once activated, the selected cycle will be maintained until changed by operator. Replace the slide with a new one, move the slide carrier to its marked starting position, and eight times a day (every three hours) it can SAMPLE UNATTENDED OVER AN ENTIRE WEEKEND. Place a new slide in Friday; remove it on Monday. It will provide 24 samples, eight for each 24-hour period, and YOU WILL NEVER HAVE TO SKIP A WEEKEND OR DAY OFF WITHOUT SAMPLING AGAIN!


 

Digital Light Meter

General Specifications

Display

13 mm (0.5") LCD (Liquid Crystal Display)
Measurement Lux, Ft-candle
Ranges
Lux- 0 to 50,000 Lux, 3 ranges Ft-candle- 0 to 5,000 Ft-candle, 3 ranges

Zero Adjustment Automatic adjustment
Over-impact Indication of "1."
Sampling Time Approx. 0.4 second.
Sensor Material Selenium Photovoltaic Cells.
Power Supply 006P DC 9V battery.
Operating Temperature 0° to 50° C (32° to 122° F)
Operating Humidity Less than 80% R.H.
Dimension 163 x 70 x 30 mm (6.4 x 2.8 x 1.2 inch)
Weight 220g (0.52 lb.)
Standard Accessories Light Sensor Instruction Manual

Electrical Specifications

Range
Resolution
Accuracy (23 ± 5°C)
Range
Resolutions
Accuracy (23 ± 5°C)
2,000 Lux 1 Lux ± (5% + 2d) 200 Ft-candle 0.1 Ft-candle ± (5% + 2d)
20,000 Lux 10 Lux ± (5% + 2d) 2,000 Ft-candle 1 Ft-candle ± (5% + 2d)
50,000 Lux 100 Lux ± (5% + 2d) 5,000 Ft-candle 10 Ft-candle ± (5% + 2d)


 

Specifications:

Display Time Constant: Adjustable from 2 to 60 seconds

Data Logging: 63,000 data points

Logging Interval: Adjustable from 1 second to 1 hour

External Dimensions: 4.2" x 7.2" x 1.5"

Probe Length: 6-1/2"

Probe Diameter: 3/4"

Operating Temperature: 41 to 113° F (5 to 45° C)

Display: 4-digit LCD, 0.6" digit height

Output: Serial Interface, RS-232 1200 baud

Power: AC adapter included/ 4 AA batteries (13.5 hours with alkaline batteries)

CO:

Sensor Type: Electro-Chemical

Range: 0-500 ppm

Accuracy: ± 3% of reading or 3 ppm, whichever is greater. (At calibration temperature. Add uncertainty of ± 0.28%/° F (0.5%/° C) for change in temperature.)

Resolution: 1 ppm

Repeatability: ± 2% of reading

Response Time: < 60 sec to 90% of final value

CO2:

Sensor Type: Non Disperse Infrared (NDIR)

Range: 0 to 5000 ppm

Accuracy: ± 3% of reading ± 50 ppm (At 77° F (25° C) Add uncertainty of ± 0.2%/° F (0.36%/° C) for change in temperature.)

Resolution: 1 ppm

Response Time: 20 seconds (For 63% of final value for 500 ppm step change.)


 

Features and Benefits

All Models
Carbon dioxide monitors with low-drift NDIR CO2 sensors to ensure stable, accurate readings
Sampling function records multiple point measurements
Models 8760 and 8762 IAQ-CALC™ IAQ Meters
Temperature and relative humidity measurements help determine thermal comfort levels
Calculates % outside air from either CO2 or temperature readings
Directly calculates dew point, wet bulb temperature, absolute humidity and humidity ratio — no psychrometric chart needed
Electrochemical sensor measures CO at outdoor air intakes, HVAC systems and parking garages (Model 8762 only)
Two-line display shows multiple parameters simultaneously


 

Questemp 15 Area Heat Stress Monitor

Specifications

Size-Dimensions include a mounted sensor assembly

9.5 in. x 7.5 in. x 5.5 in. (24 cm x 19 cm x 14 cm)
Width
Height
Depth

6.5" (165 mm)
10" (254 mm)
2" (51 mm)
Weight

28 oz. (800 g) with mounted sensor assembly.

Temperature Sensors

1000 ohm platinum RTD, 3.85 ohm/°C
Temperature Sensor Accuracy

+/- 0.5 degree C from 0°C to 100°C
+/- 1.0 degree above 100 °C
Ambient Operating Temperature Range

Questemp°15
Sensor Assembly

0 to 60 degrees C
0 to 100 degrees C
Response Time (typical)

Dry Bulb

2 minutes
Globe

12 minutes
Wet Bulb

10 minutes
Power Requirements

One 9 volt alkaline battery (NEDA #1604A) or optional AC adapter. (2-3mA typical current drain without using RS-232C, 20mA typical while using the RS-232C port.)
Battery Life

100 hours minimum (using RS-232C decreases life)


 

Questemp 10 Area Heat Stress Monitor

Specifications

Size

6.5" {165 mm)W x 10" (254mm)H x 2" (50.8}D with sensor assembly mounted
Weight

24 oz. (680 g) with sensor assembly mounted

Temperature Sensors

1000 ohm platinum RTD, 3.85 ohms/°C
Temperature Sensor Accuracy

+/- 0.5 degree C (0 to 100°C)
Ambient Operating Temperature Range

Questemp°10
Sensor Assembly

0 to 60°C
0 to 100°C
Operating Humidity Range
Electronics 0 to 95% non condensing.
Sensor Assembly 0 to 100% (not submersible)
Response Time (typical)

Dry Bulb

2 minutes
Globe

12 minutes
Wet Bulb

10 minutes
Display Range
32 to 199.9 °F in 0.1 degree increments
0 to 101.1 °C in 0.1 degree increments
Power Requirements

One 9 volt alkaline battery or optional AC adapter (2-3 (nA typical current drain)
Battery Life

150 hours typical
Effects Due to External Fields Tested for RF susceptibility with less than 0.3°C error at full strengths to 10V/m over the frequency range of 10MHz to 500MHz.


 

Questemp II Personal Heat Stress Monitor

Questemp 2 /Specifications

Accuracy

The QUESTEMP°II temperature sensor has an electronic accuracy of better than +/-0.1°C over the temperature range of 32° C to 40°C. (Body temperature range.)

The QUESTEMP° CALPROBE I Oral Temperature Probe calibrators are interchangeable between units and have an accuracy of better than 0.05°C over the temperature range of 30°C to 40°C.

Battery Life

Using one 9-volt ALKALINE (type NEDA 1604A) battery, the QUESTEMP°II, under normal usage, should last approximately 60 hours. It will also continue to operate for a minimum of 8 hours after the LOW BATTery indicator first comes on.
A 3 volt lithium battery is used as backup power for the real-time clock and the memory.

Working Temperature Range

Both the oral probe and aural sensor are meant to operate at body temperature in the range of 32°C to 40°C. The unit itself has an operating temperature range of 0°C to 70°C.
Storage
If the unit is to be stored for prolonged periods, the battery should be removed.
Operating Humidity

Operate between 0% - 95% humidity (non-condensing).
Size

2.5 x 5.1 x 1.0 inches (64 x 130 x 25mm)
Weight

Housing: 10 ounces (283 grams)
Ear Sensor Assembly: 0.15 ounces (4.2 grams)
Construction

The electronics are housed in a rugged cast aluminum case.
The ear mold is constructed from an FDA approved GEON.


 

Reuter-Stokes Mini-Wibget RSS-213 Heat Stress Monitor

Specifications

Operating Temperature Range

5°C to 55°C (40°F to 131°F)

Snesor Range

5°C (40°F) to 100°C
(212°F) (with extension cables)
Accuracy

± 0.3°C (± 0.6°F)
Response Time
3 minute nominal
Instrument Usage Time (Continuous operation)

9v. Alkaline 100 hrs
9v. Carbon-zinc 30 hrs


 

Reuter Stokes WIBGET Model RSS-214DL Heat Stress Monitor

Specifications

Accuracy

0° to 60°C ± 0.3°C
32° to140°F ± 0.5°F
Sensor Range
0° to 100°C
32° to 212°F
Instrument Readout Range

0° to 100°C
32° to 199.9°F
Instrument Operating Temperature
0° to 65°C
32° to150°F
Instrument Storage Temperature
-25° to 70°C
-10° to 158°F
Sensor Response Time
5 minutes maximum
Electronic Response Time
1 second nominal
Chart Recorder Output
10 mv/°C ± 1 mv
Battery Operating Time
15 hours nominal
Recharge Time
12 hours nominal


 

Quest M-27 Noise Datalogging Dosimeter

Specifications

Events Monitor:
Accumulates the following data for up to 16 separate events:

3 separate integrated sound levels.
3 separate noise doses.
2 time weighted averages and a sound exposure level.
Peak level, maximum level, start time, and run time.
The M-27 as an overall unit accumulates data for:

3 separate dosimeters.
3 separate 1 minute time histograms.
2 separate percent time statistical distributions.
2 separate percent dose distributions.
16 separate events.
Sound levels, peaks and maximum levels.
Run time, pause time, and elapsed or real time.
The unit displays:

Sound level, peak level, maximum level.
2 integrated average levels.
An equivalent sound level.
3 percent doses.
2 time weighted averages.
A sound exposure level.
16 separate events.
Run time, pause time, and upper limit time (the time greater than preset level).
Elapsed or real time clock (12 or 24 hour).
Calibration level.
Code of 24 internal switch settings.
The unit prints out:

A heading.
Summary of accumulated data and setup parameters.
Up to 16 separate events.
3 separate 1-, 3-, 5-, or 10-minute time histograms.
2 percent time statistical distributions.
2 percent dose statistical distributions.
Raw data for computer storage and manipulations.
Includes editing capability to print out only required data.
The M-27 internal switches select:

Exchange rates of 3, 4, 5, or 6 dB.
Criterion levels of 80, 84, 85, or 90 dB.
2 thresholds of none, 70, 75, 80, 85, or 90 dB.
2 ranges of 35-126 or 50-146 dB.
"A" or "C" frequency weighting.
Fast or slow time constant.
Upper limits of 90, 115, or 140 dB.
12 or 24 hour clocks.
8 different unit numbers.
Text, graph, or both printouts.
Serial or parallel printers.
Baud rates of 300, 600, 1200, or 2400.
Line feed, carriage return, or both.
The above features, packaged in a compact, rugged, hand-size, easy-to-use instrument, make the QUEST M-27 Noise Logging Dosimeter the "Ultimate" dosimeter.

STANDARDS: ANSI S1.4-1983 type 2
ANSI S1.25-1978
IEC 651 type 2
UL Intrinsic Safety: Class I Group C, D
Class II Group E, F
Class III
Detector: True RMS; 63 dB pulse range
Display: Liquid crystal display
Range: .01 to 2999
Annunciators: HTL, LTL, 3 dB, LOBAT, RUN, and PAUSE
Printout: RS-232 serial at 300, 600, 1200, or 2400 baud or Centronics parallel
Connector: 20 pin shrouded header
Microphone: 8 mm PZT ceramic, 36-inch cable, field replaceable
Battery: Single 9-volt alkaline, 80-hour battery life
Battery Indicator: 8-hour battery life, 1week data retention
Calibrator: External calibrator
Temperature: -15° to 50 °C operating; -40° to 60 °C storage (battery removed)
Humidity: 0 to 95% non-condensing
Magnetic Field Effects: Negligible below 50 Oersteds at 50 to 60 Hz
Size: 5½ x 2¾ x 13/8 inches(140 x 70 x 40 mm)
Weight: 14 ounces (400 grams)
Construction: Cast aluminum housing with tamper-, water-, and dust-resistant security cover


 

Quest M-28D Datalogging Noise Dosimeter

Personal Noise Dosimeter:
Accumulates noise dosimetry data.
Accumulates peak and maximum levels.
Accumulates 1-minute histograms or 10 second histograms with peak or maximum levels if de sired.
Stores 100 exceedance levels.
Is housed in a secure dust-proof case.
May be clipped on the belt or worn in the shirt pocket.
Environmental Monitor:
Accumulates up to 120 hours of 1-minute histograms. (If 10-second histograms, peak, or
maximum levels are selected, the total time will be less).
Calculates Ldn levels between 2200 and 0700 hours.
May be tripod-mounted.
The M-28D as an overall unit accumulates data for:
A noise dosimeter.
A 10-second or 1-minute time histogram.
A selectable peak and/or maximum histogram.
An exceedance level distribution.
Sound levels, peak levels, and maximum levels.
Run time, pause time and elapsed or real time.
Day/night levels (Ldn).
The M-28 D displays:
Sound level, peak level, maximum level.
An equivalent sound level (LEQ).
Percent dose (DOSE).
A time weighted average (TWA).
Run time and pause time.
Elapsed or real time clock (12- or 24- hour).
Calibration level.
Code of 24 internal switch settings.
Low battery and overload indicators.
Run, Pause, %, and dB annunciators.

The M-28D prints out:
A heading.
Summary of accumulated data and setup parameters.
A 1, 3, 5 or 10-minute histogram or a 10, 30, 60 or 120 second histogram.
Option of peak, maximum or both histograms.
An exceedance level distribution.
Raw data for computer storage and manipulations.
The M-28D provides editing capability to print out only required data.
The M-28D internal switches select:
Exchange rates of 3, 4, 5 or 6 dB.
Criterion levels of 80, 84, 85, or 90 dB.
Thresholds of none, 80, 85 or 90 dB.
2 ranges of 35-126 or 50-146 Db.
"A" or "C" frequency weighting.
Fast or Slow time constant.
12 or 24 hour clocks.
10 second or 1 minute histograms.
Peak, maximum or both histograms.
Text, graph or both printouts.
Specifications

Standards:
ANSI SI .4-1983 type 2
ANSI SI..25-1978 type 2
IEC 651 type 2
IEC 804 type 2

UL Intrinsic Safety:
Class I Group C,D
Class II Group E,F
Class III

Detector:
True RMS; 63 dB pulse range

Display:
Liquid Crystal Display
Range:
.01 to 2999
Annunciators:
OL, %, dB, LOBAT, RUN, and PAUSE

Data Output:
RS-232 serial (at 1200, 2400, 4800, or 9600 baud) or Centronics parallel.
Connector:
20-pin shrouded header.
Microphone:
8 mm PZT ceramic, 48 inch cable, field replaceable
Battery:
Single 9-volt alkaline, 80-hour battery life.

Battery indicator:
From the time of the first low battery indication, 8-hours of battery life remain with the unit on. One week of data retention remains with the unit off.

Calibrator;
External acoustic calibrator
Temperature:
-15° to +50°C operating; -40° to +60°C storage (battery removed)

Humidity:
0 to 95% non-condensing

Magnetic Field:
Negligible below 50 Oersteds at 50 to 60 Hz Effects
Size:
5.5 x 2.8 x 1.4 inches (140 x 70 x 40 mm)

Weight:
14 ounces (400 grams)
Construction:
Cast aluminum housing with tamper-, water-, and dust-resistant security cove


 

Quest 2400

Specifications

Standards:
Meets or exceeds ANSI S1.4-1983, Type 2 and relevant sections of IEC 651-1979, Type 2.

Display:
3 1/2 Digit Liquid Crystal Display. Level display indicates to 0.1 dB resolution. Annunciator is included for Battery Check. LED indicators are used for overrange and underrange conditions.

Modes of Operation:
Measures sound pressure level (SPL) or maximum level (MAX).

Range:
30 to 140 dBA
40 to 140 dBC

AC Gain Calibration:
External calibration adjustment available on front of meter near the microphone. Calibrate using a lOOOHz acoustic calibrator that is properly adapted to the microphone.

Frequency Weighting Networks:
A, and C.
Meter Response:
Slow and Fast.

Microphone:
Removable .83-inch (21mm) prepolarized condenser (electret) microphone.
AC Output:
0.85V RMS at 100 dB on LOW range.
8.5mV RMS at 100 dB on HIGH range.
The output impedance is 1 Kohms.
1/8 inch phone jack.

DC Output:
OVDC +/- 15MV at 100 dB.
Each 0.167V change equals 10dB (1V/60dB).
The output impedance is 1 Kohms.
1/8 inch phone jack.
Detector:
True RMS.
Crest Factor:
15 (23dB) up to 88dB LOW Range, 128dB HIGH Range.
5 (l4dB) up to 98dB LOW range, l38dB HIGH Range.
3 (10dB) up to l03dB LOW range, l43dB HIGH Range. Crest factor is always sufficient to handle the signal if the overload indicator does not light.
Overload indication:
A red LED indicates overload.
Attenuator Accuracy:
Within 0.5dB from 20-8000 Hz, within 1.0 dB from 20-12,500 Hz.


 

Quest 2700 Sound Level Meter

Specifications

Standards: Meets or exceeds ANSI S1.4-1983, Type 2 and relevant sections of IEC 651-1979. Type 2(I).

Display: 3 1/2 Digit Liquid Crystal Display with an additional Quasi-Analogue 60 dB indicator in 2 dB increments. Level display indicates to O.1 dB resolution. Annunciators are included for Battery Check, Hold, and Overload Indication.

Modes of Operation: Measures Sound Pressure Level (SPL) and Maximum Level (MAX). Peak Level (PEAK) and Impulse Level (IMP) can also be measured.

Minimum Measurement: Meter only; With Model QE7052 Microphone — 35 dBA. Using Linear Weighting with an Octave Filter Set. The minimum measurement varies depending on the filter frequency selected.

Maximum Measurement: With Model QE7052 Microphone - 120 dB with 20 dB Great Factor. (140 dB if measuring a sinusoidal signal.) Overload indication will occur if upper range is exceeded.

Frequency Weighting Networks: A, B, C and Linear. When using a filter set, any one of the weightings may be selected.

Meter Response: Slow, Fast, Impulse, and Peak. (The Peak onset time constant is less than 50 microseconds). Peak measurements may be made in either A, B, C, or Linear Weighting.

Microphone: Model QE7052, Removable .5-inch prepolarized condenser (electret) microphone.

Preamp: Removable; The input impedance is greater than 1G ohm in parallel with 35 pF. The preamp will drive up to 100 feet of cable.

Meter Input: The input impedance is 1 Megohm in series with 0.1 MFD. The maximum sinusoidal input voltage is 10V RMS.

AC Output: 3.16 V RMS at full scale (60 dB). (3.8 V RMS maximum) The output impedance is 3.2K ohms. Connected equipment should be at least 10K ohms. The output can be shorted without damaging the meter or changing the meter reading.

DC Output: 0 to l.00V DC; 60 dB span. Each 0.167V change equals 10 dB. Connected equipment should be at least 10K ohms. The output can be shorted without damaging the meter or changing the meter reading.

Frequency Range: 4 Hz (-3dB) to 50 kHz (-3dB) on linear weighting, meter only. (Subject to microphone limitations.)

Reference Range: 60 to 120 dB Range setting

Reference SPL: 94 dB

Reference Frequency: 1 kHz


 

QUEST 2800 Technical Specifications

Integrating:
Yes

Measurement Range:
Meter Only: 30 to 140 dBA
With External Filters: 0 to 140 dBA

Microphone:
Size: 0.5” (1 cm)
Detachable Preamp
Maximum Cable Length 50 Ft. (15 m )

Frequency Weighting:
A, B, C, Lin

External Filters:
Optional

Response Time Constants:
Fast
Slow
Impulse
Peak

Outputs:
AC/DC, RS-232

Temperature Range:
Operating: 14 to 122°F (-10 to 50°C)
Storage: -4 to 140°F (-20 to 60°C) (battery removed)

Batteries:
(2) 9V Alkaline

Size:
3.3” x 8.2” x 1.8” (8.5 x 21 x 4.7 cm) (add 0.5” for microphone)

Weight:
24 oz. (680 g)

Standards:

2800:
Type 2, ANSI S1.43-1997, IEC60651-1979, IEC60804-1985

 

QUEST OB-300 Technical Specifications

The OB-300 combination 1/3 & 1/1 Octave Band Filter Set gives you a choice of measuring 33 one-third-octave bands or 11 standard full octave bands. The OB-300 will manually or automatically sequence through each octave or third octave band and display the measured level on the sound level meter

Standards:
ANSI S1.11-1986, Order 3, Type 2, Sub-Type C and IEC R225-1966.
Center Frequencies:
(1/3 Mode) 33 frequencies from 12.5 Hz to 20 kHz. (1/1 Mode) 11 frequencies from 16 Hz to 16 kHz.
Frequency Selection:
Full manual control or automatic sequential stepping through each frequency.
Power Source:
Sound Level Meter
Size:
3.3 x 4.2 x 1.8 inches (84 x 107 x 47 mm)


 

Metrosonics db-3100 Metrologger Noise Dosimeter

Specifications

DATA DISPLAY
Display Type: Large 3½ digit LCD display
Display Resolution: 0.1 dB
Display Update: Current sound level updated 4 times per second

DIGITAL COMMUNICATIONS

Interface: 3-wire RS-232C; uses X-on/X-off
Baud Rate: 300, 1200, 4800 formatted, 4800 memory dump
Report Width: 80-column
Format: ASCII, 1 start bit, 8 data bits, 1 stop bit

OUTPUT MODES

Printer: Preformatted data for RS-232C printer or terminal
Memory Dump: Unformatted data to computer
Header: Precedes each formatted report - Identifies logger model, serial number and software version, date and time of report, calibrator information, time and date of last calibration, display range, weighting, exchange rate and averaging response

ENVIRONMENTAL

Operating Temp.: -4 to +140°F (-20 to +60°C)
LCD Working Temp.: +14 to +122°F (-10 to +50°C)
Humidity: To 90% non-condensing. Short term complete water immersion, except microphone

POWER

Battery Type: 9V alkaline, 1604A, primary
Battery Operating Life: At least 40 hours @ 25°C
Data Retention: 30 days

PHYSICAL

Case: Anodized aluminum extrusion
Size: 3.0 x 4.8 x 0.9 inch (7.6 x 12.2 x 2.3 cm)
Weight: 12oz.(0.3kg)

INPUT
db-3100 Microphone: Metrosonics 1/4" pendant microphone, rugged, miniature ceramic type, with 1-meter captive cable
db-3100 Oper. Range: 40 to 140 dB
db-3100 Dynamic Range: 100.0 dB
db-3100 Amplitude Linearity: + 0.7 dB
Amplitude Resolution: 0.1 dB
Detector: True RMS
Sample Rate: Slow: 16 samples/sec.; Fast: 64 samples/sec.
Peak Range: 28 dB
db-3100 Applicable Standards: Type 2: ANSI S1.4-1983, ANSI S1.25-1978, IEC 651, IEC 804

USER-PROGRAMMABLE PARAMETERS

Frequency Response: A or C weighted
Averaging Response: Slow or Fast
Exchange (Doubling) Rate: 3, 4, 5, 6 dB
Criterion Level: 60 to 100 dB
Dose Period: 4, 6, 8, 10, 12, 16, 18 hours
Exposure Level: % dose or Pa2h
Cutoff (Threshold) Levels: Two, 40 to 140 dBA
Ceiling Level: 40 to 140 dB
Real Time Clock: Date and Time at Computer
Schedule Run: Date, Time, Length
Time History Interval: Hours, Minutes, Seconds
Time History Data Saved: Lavg, Lmax, Lpk, 2 Ln values (either combined for all tests or separate for each individual test)
Security Code: 3-digit

DATA STORAGE

Capacity: 725 intervals if all time history statistics are saved

OPERATING CONTROLS

Push Buttons: 3 sealed




 

TMX 410 & TMX 412 Four-Range Monitors

Specifications

Measuring Range:

LEL:
0 to 100% LEL
O2:
0 to 30% by Vol

CO:
0 to 999 ppm
H2S:
0 to 999 ppm
SO2:
0 to 99.9 ppm
C12:
0 to 99.9 ppm
N02:
0 to 99.9 ppm
Temperature Range:

Continuous -15 to +40°C
Humidity Range:
15 to 90% RH (non-condensing)
Operating Time:
10± hours per fully charged battery
Charge Time:
4.5 hours
Power Source:
Rechargeable ni-cad batteries
Dimensions:
4.75 x 2.75 x 2 inches
Unit Weight: 1.625 pounds
Shipping Weight: 6 pounds
ISC's TMX410 and TMX412 multi-gas monitors detect and monitor up to four gases continuously and simultaneously. Users determine how the TMX is to be configured. The base model comes standard with Oxygen and LEL, with a choice of two additional sensors-Carbon Monoxide, Hydrogen Sulfide, Nitrogen Dioxide, Sulfur Dioxide or Chlorine. The optional sampling pump with 10 feet of tubing permits either unit to sample air in remote or confined areas up to 100 feet away. Both pumps are supplied with a charger.

The all new TMX412 comes standard with an internal hygiene board which calculates STEL and TWA values and stores up to 120 hours of data with four sensors installed. Software and cabling are included. A unique feature to the unit is also a single, large button control for all functions, making it easier to operate when wearing heavy or awkward clothing.


 

Sensor Specifications:

Gas Range Resolution
Carbon Monoxide (CO) 0-999 ppm 1 ppm
Hyrdrogen Sulfide (H2S)) 0-500 ppm 1 ppm
Oxygen (O2) 0-30% 0.1%
Combustible (LEL) 0-100% LEL 1%

Temperature and Hudity Range:

Operating Temperature:
-20°C to +50°C (-4 to 122°F),typical toxic/oxygen
0° to 40°C (32 to 104°F), for LEL sensor only per C22.2 No. 152
Operating Humidity:
15-95% RH, typical 0-99%, intermittent, non-condensing
Charger Specifications:

Runtimes:
18 hours diffusion, 12 hours with pump


 

JEROME 411 GOLD FILM MERCURY VAPOR ANALYZER

Specifications

Sensitivity:

0.003 mg/m3 Hg
Precision:
5% Relative Standard Deviation
@ .107mg/m3 Hg
Accuracy:
+ /.5% @ 0.107 mg/m3 Hg

Range :
0.000 to 1.999 mg/m3 Hg
Response Time
SAMPLE mode:
SURVEY mode:

10 seconds
1 seconds
Flow Rate:
750cc/min
0.75 liters/min = 750cc/min
Power Requirements:
115VAC or 230VAC
115 watts maximum
Batteries:
Rechargeable Nickel-Cadmium
Construction:

Aluminum Alloy
Dimensions:
6" W X 13" L X 4" H
Weight:
5 pounds
Digital Meter:
Liquid Crystal Display
Operating Environmental Range:
0- 40°C, non-condensing, non-explosive
Data Output:
Digital, Serial; Voltage levels:
Logic 0 = +5V, Logic 1 = 0V
Transfer Rate: 150 Bits/Second
Data String: 1 Start Bit (+5V)
7 Data Bits (ASCII Format) LSB 1st
1 Parity Bit (Always 0) 2 Stop Bits (0V)


 

 

New patented planar, dual channel PI detector

New super bright UV lamp

Increased sensitivity down to 1 ppb

Reduced humidity interference

Improved linearity

Easily accessible lamp and sensor

Strong, built-in sample draw pump with pump stall feature

Prevents liquid flow into the monitor

Rechargeable battery for 10 hours of continuous monitoring

Smart battery charging

Automotive charger available

Large keys operable with 3 layers of gloves

Large easy to read back light display

Alarm activated

Darkness or manually activated

Preset alarm thresholds for STEL, TWA, low and high level peak values

Audio buzzer and flashing LED display will be activated when the limits are exceeded

15,000 point data logging storage capacity for data download to PC

Rubber protective boot

102 built-in correction factors from a RAE list of 250+ chemicals

User selectable hygiene and survey modes

Protected from portable radios


 

RAE MINIRAE PID

Specifications

Size: 7.1"L x 2.7"W x 1.8"H
(18.0 cm x 6.9 cm x 4.6 cm)
Weight: 18 oz with battery (0.510 kg)
Detector: Interchangeable 10.6eV or 11.7eV electrodeless ultraviolet discharge lamp with Teflon/stainless steel chamber
Operating Hours : 10 hours continuous operation
Battery: Two rechargeable, 6V, 500 mAh, sealed, lead-acid. Field replaceable.
Gas Sampling : Piston pump with >400 ml/min intake flow rate
Gas Inlet Prob: 6" flexible 5/32" tube
Gas Outlet: 5/32" diameter barb fitting
Attachment: wrist strap
Display: 7 digit LCD with LED back light
Analog Output : 0 to 1 V
Range: 0 - 999.0 ppm with 0.1 ppm resolution, 1000-1999 ppm with 1 ppm resolution


Gas outlet port for connection to sample collection bag
Multi-interface jack for connection to PC, audio interface or analog output




 

HNU PID DL-101

Specifications

Certification: designed to meet Class I, Division II, Groups ABCD
Detection Principle: photoionization
*Range: 0.1 to 2000 ppm
*Linear Range: 0.1 to 400 ppm
*Detection Limit: 0.1 ppm
*Repeatability: +/-l%
Response Time: <3 seconds to 90% response
Inlet flow: 225 cc/min
Ambient Humidity: to 95% RH (noncondensing)
Ambient Operating Temperature: to 40° C (temperature compensated so that a 20° C change in temperature corresponds in reading of <+/-2% full scale at maximum sensitivity)
Calibration: benzene referred default plus 11 user defined calibrations
Interchangeable lamps: 11.7, 10.2, and 9.5 eV
Dimensions: probe (8 in. x 3 in.)
readout module (8 x 3 x 6 in.)
cable (36 in.)
Weight:
probe (3 lbs.)
readout module (4 lbs.)
total weight (7 lbs.)

Operating Time on BatteryContinuous Use: >eight hours continuous use at 23° C
Approximately 6.4 hours at 0° C.
Recharge Time from full discharge: 12 to 14 hours
Recorder Output: 2 V +/-3% at 2000 ppm
NOTE * When equipped with 10.2eV lamp and measuring benzene. Values vary for other compounds, conditions, and lamp used. Use of multipoint calibration can increase the linear range.